{"id":20721,"date":"2020-09-15T14:28:48","date_gmt":"2020-09-15T12:28:48","guid":{"rendered":"https://www.istec.com/cn/?p=20721"},"modified":"2026-07-27T10:31:03","modified_gmt":"2026-07-27T08:31:03","slug":"3-ways-of-monitoring-your-pumps-for-cavitation","status":"publish","type":"post","link":"https://www.istec.com/cn/3-ways-of-monitoring-your-pumps-for-cavitation/","title":{"rendered":"3 ways of monitoring your pumps for cavitation"},"content":{"rendered":"<p><span class=\"large-p\">Cavitation is a widely known problem that occurs to pumps and results in significant damage and other undesirable consequences. To avoid damage a pump should be monitored for the formation and occurrence of cavitation. This article describes different options regarding cavitation monitoring and protection to fit any application.</span></p>\n<p>Cavitation is the formation of air bubbles inside a pump as a result of a pressure drop of the flowing liquid. As these air bubbles move, the pressure increases, resulting in the implosion of the air bubbles. The implosion of the air bubbles on the surface of the pump housing or impeller results in damage and performance issues. Two types of cavitation are distinguished:</p>\n<ol>\n<li><strong>Suction cavitation</strong> can occur when a pump is under low pressure or high vacuum conditions. As the pump is not receiving enough flow, bubbles will form on the impeller. When these bubbles carry over to the other side (discharge) of the pump and are compressed with liquid, they implode.</li>\n</ol>\n<ol start=\"2\">\n<li><strong>Discharge cavitation</strong> can occur when the pressure during the discharge is excessively high. Due to the high pressure it becomes hard for the fluid to leave the pump, causing it to circulate inside the pump. This could cause a vacuum and the formation of air bubbles, which in turn causes damage to both the impeller and the pump housing.</li>\n</ol>\n<p>Long-term cavitation leads to pumping failures, such as the destruction of the pump’s housing and impeller. Other effects of cavitation are excessive noise and energy usage.</p>\n<figure id=\"attachment_20712\" aria-describedby=\"caption-attachment-20712\" style=\"width: 300px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-20712 size-medium\" src=\"https://www.istec.com/wp-content/uploads/2020/09/AdobeStock_345620346-300x225.jpeg\" alt=\"\" width=\"300\" height=\"225\" /><figcaption id=\"caption-attachment-20712\" class=\"wp-caption-text\"><span class=\"small-p\">Figure 1. <em>An example of impeller damage as a result of cavitation.</em></span></figcaption></figure>\n<h2>Configurations to monitor cavitation</h2>\n<p>There are different configurations to be able to monitor cavitation. Which configuration fits the application best depends on the application and/or customer demands. Three configurations are distinguished:</p>\n<h3>1. 4-20mA sensor</h3>\n<p>When using a 4-20mA sensor the customer is required to determine the desirable limit value and configure this in the DCS/PLC. The DCS/PLC is then used to generate an alarm when this limit value is exceeded. To determine the limit value a cavitation situation must be created in the pump. A large disadvantage of 4-20mA sensors is that it gives an overall value of the vibrations, making it impossible to distinguish cavitation from other factors that may cause excessive vibrations. A typical configuration when using a 4-20mA sensor looks as follows:</p>\n<figure id=\"attachment_20713\" aria-describedby=\"caption-attachment-20713\" style=\"width: 673px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-20713 size-full\" src=\"https://www.istec.com/wp-content/uploads/2020/09/4-20mA-sensor-config.png\" alt=\"\" width=\"673\" height=\"248\" srcset=\"https://img.istec.com/2020/09/4-20mA-sensor-config.png 673w, https://img.istec.com/2020/09/4-20mA-sensor-config-300x111.png 300w\" sizes=\"auto, (max-width: 673px) 100vw, 673px\" /><figcaption id=\"caption-attachment-20713\" class=\"wp-caption-text\"><span class=\"small-p\">Figure 2. A typical application using a 4-20mA sensor. </span></figcaption></figure>\n<h3>2. Programmable transmitter</h3>\n<p>As with the aforementioned configuration the cavitation test must be performed by the customer. The frequency at which cavitation occurs is determined and then used to filter the data. The desired alarm value is send to a DCS/PLC or used to trigger a relay. A standard 100mV/g accelerometer is used to send the raw vibration signal to the transmitter. The transmitter processes this signal and provides two 4-20mA signals that can be calculated over two different frequency bands. This makes it possible to distinguish between vibrations as a result of cavitation and those caused by other deviations such as unbalance and bearing damage. A typical configuration looks as follows:</p>\n<figure id=\"attachment_20714\" aria-describedby=\"caption-attachment-20714\" style=\"width: 1000px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-20714\" src=\"https://www.istec.com/wp-content/uploads/2020/09/Intelligent-transmitter-config.png\" alt=\"\" width=\"1000\" height=\"201\" srcset=\"https://img.istec.com/2020/09/Intelligent-transmitter-config.png 1097w, https://img.istec.com/2020/09/Intelligent-transmitter-config-300x60.png 300w, https://img.istec.com/2020/09/Intelligent-transmitter-config-730x146.png 730w, https://img.istec.com/2020/09/Intelligent-transmitter-config-768x154.png 768w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" /><figcaption id=\"caption-attachment-20714\" class=\"wp-caption-text\"><span class=\"small-p\">Figure 3. <em>A typical configuration using a programmable (intelligent) transmitter.</em></span></figcaption></figure>\n<h3>3. Condition monitoring transmitter (VibroSmart)</h3>\n<p>This configuration uses the same sensors as the transmitter configuration. Like the previous configuration, the 4-20mA signal is calculated within a freely configurable frequency. However, a more advanced type of transmitter is used. Through Modbus, up to 10 different calculated outputs per signal can be generated. This makes it possible to distinguish between specific machine errors in the control system. Some machine errors have a specific frequency range, which can be calculated independently. This makes it possible to directly attribute deviations in vibration behaviour to a specific error and immediately initiate the necessary action. Unfiltered data can be saved on a local PC or sent through a network, which enables remote condition monitoring.</p>\n<p><span class=\"alt-link\"><a href=\"https://www.istec.com/cn/what-hardware-is-required-for-a-remote-vibration-monitoring-system/\">Read about remote condition monitoring configurations here »</a></span></p>\n<p>A typical configuration:</p>\n<figure id=\"attachment_20715\" aria-describedby=\"caption-attachment-20715\" style=\"width: 1000px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-20715\" src=\"https://www.istec.com/wp-content/uploads/2020/09/Vibrosmart-config.png\" alt=\"\" width=\"1000\" height=\"396\" srcset=\"https://img.istec.com/2020/09/Vibrosmart-config.png 1008w, https://img.istec.com/2020/09/Vibrosmart-config-300x119.png 300w, https://img.istec.com/2020/09/Vibrosmart-config-730x289.png 730w, https://img.istec.com/2020/09/Vibrosmart-config-768x304.png 768w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" /><figcaption id=\"caption-attachment-20715\" class=\"wp-caption-text\"><span class=\"small-p\">Figure 4. <em>A typical configuration using a condition monitoring transmitter.</em></span></figcaption></figure>\n","protected":false},"excerpt":{"rendered":"<p>Cavitation is a widely known problem that occurs to pumps and results in significant damage and other undesirable consequences. To avoid damage a pump should be monitored for the formation and occurrence of cavitation. This article describes different options regarding cavitation monitoring and protection to fit any application. Cavitation is the formation of air bubbles &hellip; </p>\n","protected":false},"author":3,"featured_media":20716,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[98],"topics":[266,265],"class_list":["post-20721","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized","topics-recipsys","topics-knowledge"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.7 - https://yoast.com/product/yoast-seo-wordpress/ -->\n<title>3 ways of monitoring your pumps for cavitation &#8212; Istec</title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" />\n<link rel=\"canonical\" href=\"https://www.istec.com/cn/3-ways-of-monitoring-your-pumps-for-cavitation/\" />\n<meta property=\"og:locale\" content=\"zh_CN\" />\n<meta property=\"og:type\" content=\"article\" />\n<meta property=\"og:title\" content=\"3 ways of monitoring your pumps for cavitation &#8212; Istec\" />\n<meta property=\"og:description\" content=\"Cavitation is a widely known problem that occurs to pumps and results in significant damage and other undesirable consequences. To avoid damage a pump should be monitored for the formation and occurrence of cavitation. This article describes different options regarding cavitation monitoring and protection to fit any application. Cavitation is the formation of air bubbles &hellip;\" />\n<meta property=\"og:url\" content=\"https://www.istec.com/cn/3-ways-of-monitoring-your-pumps-for-cavitation/\" />\n<meta property=\"og:site_name\" content=\"Istec\" />\n<meta property=\"article:published_time\" content=\"2020-09-15T12:28:48+00:00\" />\n<meta property=\"article:modified_time\" content=\"2026-07-27T08:31:03+00:00\" />\n<meta property=\"og:image\" content=\"https://img.istec.com/2020/09/uitgelicht-1.jpeg?q=65\" />\n\t<meta property=\"og:image:width\" content=\"730\" />\n\t<meta property=\"og:image:height\" content=\"270\" />\n\t<meta property=\"og:image:type\" content=\"image/jpeg\" />\n<meta name=\"author\" content=\"istecadmin\" />\n<meta name=\"twitter:card\" content=\"summary_large_image\" />\n<meta name=\"twitter:label1\" content=\"Written by\" />\n\t<meta name=\"twitter:data1\" content=\"istecadmin\" />\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" />\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" />\n<script type=\"application/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\/\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\/\\/www.istec.com\\/3-ways-of-monitoring-your-pumps-for-cavitation\\/#article\",\"isPartOf\":{\"@id\":\"https:\\/\\/www.istec.com\\/3-ways-of-monitoring-your-pumps-for-cavitation\\/\"},\"author\":{\"name\":\"istecadmin\",\"@id\":\"https:\\/\\/www.istec.com\\/#\\/schema\\/person\\/04b7a48a774cc6803bde480e419841db\"},\"headline\":\"3 ways of monitoring your pumps for cavitation\",\"datePublished\":\"2020-09-15T12:28:48+00:00\",\"dateModified\":\"2026-07-27T08:31:03+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\/\\/www.istec.com\\/3-ways-of-monitoring-your-pumps-for-cavitation\\/\"},\"wordCount\":664,\"publisher\":{\"@id\":\"https:\\/\\/www.istec.com\\/#organization\"},\"image\":{\"@id\":\"https:\\/\\/www.istec.com\\/3-ways-of-monitoring-your-pumps-for-cavitation\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\/\\/img.istec.com\\/2020\\/09\\/uitgelicht-1.jpeg?q=65\",\"inLanguage\":\"zh-CN\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\/\\/www.istec.com\\/3-ways-of-monitoring-your-pumps-for-cavitation\\/\",\"url\":\"https:\\/\\/www.istec.com\\/3-ways-of-monitoring-your-pumps-for-cavitation\\/\",\"name\":\"3 ways of monitoring your pumps for cavitation &#8212; Istec\",\"isPartOf\":{\"@id\":\"https:\\/\\/www.istec.com\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\/\\/www.istec.com\\/3-ways-of-monitoring-your-pumps-for-cavitation\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\/\\/www.istec.com\\/3-ways-of-monitoring-your-pumps-for-cavitation\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\/\\/img.istec.com\\/2020\\/09\\/uitgelicht-1.jpeg?q=65\",\"datePublished\":\"2020-09-15T12:28:48+00:00\",\"dateModified\":\"2026-07-27T08:31:03+00:00\",\"breadcrumb\":{\"@id\":\"https:\\/\\/www.istec.com\\/3-ways-of-monitoring-your-pumps-for-cavitation\\/#breadcrumb\"},\"inLanguage\":\"zh-CN\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\/\\/www.istec.com\\/3-ways-of-monitoring-your-pumps-for-cavitation\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-CN\",\"@id\":\"https:\\/\\/www.istec.com\\/3-ways-of-monitoring-your-pumps-for-cavitation\\/#primaryimage\",\"url\":\"https:\\/\\/img.istec.com\\/2020\\/09\\/uitgelicht-1.jpeg?q=65\",\"contentUrl\":\"https:\\/\\/img.istec.com\\/2020\\/09\\/uitgelicht-1.jpeg?q=65\",\"width\":730,\"height\":270,\"caption\":\"Water supply system. Quarry for the extraction of minerals Mine in the mountain. Slurry pressure pump wheel. Accident from friction and quits, defect - hole. Color image\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\/\\/www.istec.com\\/3-ways-of-monitoring-your-pumps-for-cavitation\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\/\\/www.istec.com\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"3 ways of monitoring your pumps for cavitation\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\/\\/www.istec.com\\/#website\",\"url\":\"https:\\/\\/www.istec.com\\/\",\"name\":\"Istec\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\/\\/www.istec.com\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\/\\/www.istec.com\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-CN\"},{\"@type\":\"Organization\",\"@id\":\"https:\\/\\/www.istec.com\\/#organization\",\"name\":\"Istec\",\"url\":\"https:\\/\\/www.istec.com\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-CN\",\"@id\":\"https:\\/\\/www.istec.com\\/#\\/schema\\/logo\\/image\\/\",\"url\":\"https:\\/\\/img.istec.com\\/2018\\/01\\/istec-international-logo.jpg?q=65\",\"contentUrl\":\"https:\\/\\/img.istec.com\\/2018\\/01\\/istec-international-logo.jpg?q=65\",\"width\":83,\"height\":88,\"caption\":\"Istec\"},\"image\":{\"@id\":\"https:\\/\\/www.istec.com\\/#\\/schema\\/logo\\/image\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\/\\/www.istec.com\\/#\\/schema\\/person\\/04b7a48a774cc6803bde480e419841db\",\"name\":\"istecadmin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-CN\",\"@id\":\"https:\\/\\/secure.gravatar.com\\/avatar\\/ef2104d69abb108ecc953f2504e75cff42eef5e48ce6e93be2b0814a1056f0aa?s=96&d=mm&r=g\",\"url\":\"https:\\/\\/secure.gravatar.com\\/avatar\\/ef2104d69abb108ecc953f2504e75cff42eef5e48ce6e93be2b0814a1056f0aa?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\/\\/secure.gravatar.com\\/avatar\\/ef2104d69abb108ecc953f2504e75cff42eef5e48ce6e93be2b0814a1056f0aa?s=96&d=mm&r=g\",\"caption\":\"istecadmin\"},\"url\":\"https:\\/\\/www.istec.com\\/specialist\\/istecadmin\\/\"}]}</script>\n<!-- / Yoast SEO plugin. -->","yoast_head_json":{"title":"监测泵空化现象的3种方法 — Istec","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https://www.istec.com/cn/3-ways-of-monitoring-your-pumps-for-cavitation/","og_locale":"zh_CN","og_type":"article","og_title":"3 ways of monitoring your pumps for cavitation &#8212; Istec","og_description":"Cavitation is a widely known problem that occurs to pumps and results in significant damage and other undesirable consequences. To avoid damage a pump should be monitored for the formation and occurrence of cavitation. This article describes different options regarding cavitation monitoring and protection to fit any application. Cavitation is the formation of air bubbles &hellip;","og_url":"https://www.istec.com/cn/3-ways-of-monitoring-your-pumps-for-cavitation/","og_site_name":"Istec","article_published_time":"2020-09-15T12:28:48+00:00","article_modified_time":"2026-07-27T08:31:03+00:00","og_image":[{"width":730,"height":270,"url":"https://img.istec.com/2020/09/uitgelicht-1.jpeg?q=65","type":"image/jpeg"}],"author":"istecadmin","twitter_card":"summary_large_image","twitter_misc":{"Written by":"istecadmin","Est. reading time":"4 minutes"},"schema":{"@context":"https://schema.org","@graph":[{"@type":"Article","@id":"https://www.istec.com/cn/3-ways-of-monitoring-your-pumps-for-cavitation/#article","isPartOf":{"@id":"https://www.istec.com/cn/3-ways-of-monitoring-your-pumps-for-cavitation/"},"author":{"name":"istecadmin","@id":"https://www.istec.com/cn/#/schema/person/04b7a48a774cc6803bde480e419841db"},"headline":"3 ways of monitoring your pumps for cavitation","datePublished":"2020-09-15T12:28:48+00:00","dateModified":"2026-07-27T08:31:03+00:00","mainEntityOfPage":{"@id":"https://www.istec.com/cn/3-ways-of-monitoring-your-pumps-for-cavitation/"},"wordCount":664,"publisher":{"@id":"https://www.istec.com/cn/#organization"},"image":{"@id":"https://www.istec.com/cn/3-ways-of-monitoring-your-pumps-for-cavitation/#primaryimage"},"thumbnailUrl":"https://img.istec.com/2020/09/uitgelicht-1.jpeg?q=65","inLanguage":"zh-CN"},{"@type":"WebPage","@id":"https://www.istec.com/cn/3-ways-of-monitoring-your-pumps-for-cavitation/","url":"https://www.istec.com/cn/3-ways-of-monitoring-your-pumps-for-cavitation/","name":"3 ways of monitoring your pumps for cavitation &#8212; Istec","isPartOf":{"@id":"https://www.istec.com/cn/#website"},"primaryImageOfPage":{"@id":"https://www.istec.com/cn/3-ways-of-monitoring-your-pumps-for-cavitation/#primaryimage"},"image":{"@id":"https://www.istec.com/cn/3-ways-of-monitoring-your-pumps-for-cavitation/#primaryimage"},"thumbnailUrl":"https://img.istec.com/2020/09/uitgelicht-1.jpeg?q=65","datePublished":"2020-09-15T12:28:48+00:00","dateModified":"2026-07-27T08:31:03+00:00","breadcrumb":{"@id":"https://www.istec.com/cn/3-ways-of-monitoring-your-pumps-for-cavitation/#breadcrumb"},"inLanguage":"zh-CN","potentialAction":[{"@type":"ReadAction","target":["https://www.istec.com/cn/3-ways-of-monitoring-your-pumps-for-cavitation/"]}]},{"@type":"ImageObject","inLanguage":"zh-CN","@id":"https://www.istec.com/cn/3-ways-of-monitoring-your-pumps-for-cavitation/#primaryimage","url":"https://img.istec.com/2020/09/uitgelicht-1.jpeg?q=65","contentUrl":"https://img.istec.com/2020/09/uitgelicht-1.jpeg?q=65","width":730,"height":270,"caption":"Water supply system. Quarry for the extraction of minerals Mine in the mountain. Slurry pressure pump wheel. Accident from friction and quits, defect - hole. Color image"},{"@type":"BreadcrumbList","@id":"https://www.istec.com/cn/3-ways-of-monitoring-your-pumps-for-cavitation/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://www.istec.com/cn/"},{"@type":"ListItem","position":2,"name":"3 ways of monitoring your pumps for cavitation"}]},{"@type":"WebSite","@id":"https://www.istec.com/cn/#website","url":"https://www.istec.com/cn/","name":"Istec","description":"","publisher":{"@id":"https://www.istec.com/cn/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://www.istec.com/cn/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-CN"},{"@type":"Organization","@id":"https://www.istec.com/cn/#organization","name":"Istec","url":"https://www.istec.com/cn/","logo":{"@type":"ImageObject","inLanguage":"zh-CN","@id":"https://www.istec.com/cn/#/schema/logo/image/","url":"https://img.istec.com/2018/01/istec-international-logo.jpg?q=65","contentUrl":"https://img.istec.com/2018/01/istec-international-logo.jpg?q=65","width":83,"height":88,"caption":"Istec"},"image":{"@id":"https://www.istec.com/cn/#/schema/logo/image/"}},{"@type":"Person","@id":"https://www.istec.com/cn/#/schema/person/04b7a48a774cc6803bde480e419841db","name":"istecadmin","image":{"@type":"ImageObject","inLanguage":"zh-CN","@id":"https://secure.gravatar.com/avatar/ef2104d69abb108ecc953f2504e75cff42eef5e48ce6e93be2b0814a1056f0aa?s=96&d=mm&r=g","url":"https://secure.gravatar.com/avatar/ef2104d69abb108ecc953f2504e75cff42eef5e48ce6e93be2b0814a1056f0aa?s=96&d=mm&r=g","contentUrl":"https://secure.gravatar.com/avatar/ef2104d69abb108ecc953f2504e75cff42eef5e48ce6e93be2b0814a1056f0aa?s=96&d=mm&r=g","caption":"istecadmin"},"url":"https://www.istec.com/cn/specialist/istecadmin/"}]}},"_links":{"self":[{"href":"https://www.istec.com/cn/wp-json/wp/v2/posts/20721","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https://www.istec.com/cn/wp-json/wp/v2/posts"}],"about":[{"href":"https://www.istec.com/cn/wp-json/wp/v2/types/post"}],"author":[{"embeddable":true,"href":"https://www.istec.com/cn/wp-json/wp/v2/users/3"}],"replies":[{"embeddable":true,"href":"https://www.istec.com/cn/wp-json/wp/v2/comments?post=20721"}],"version-history":[{"count":10,"href":"https://www.istec.com/cn/wp-json/wp/v2/posts/20721/revisions"}],"predecessor-version":[{"id":37510,"href":"https://www.istec.com/cn/wp-json/wp/v2/posts/20721/revisions/37510"}],"wp:featuredmedia":[{"embeddable":true,"href":"https://www.istec.com/cn/wp-json/wp/v2/media/20716"}],"wp:attachment":[{"href":"https://www.istec.com/cn/wp-json/wp/v2/media?parent=20721"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https://www.istec.com/cn/wp-json/wp/v2/categories?post=20721"},{"taxonomy":"topics","embeddable":true,"href":"https://www.istec.com/cn/wp-json/wp/v2/topics?post=20721"}],"curies":[{"name":"wp","href":"https://api.w.org/{rel}","templated":true}]}}