{"id":17781,"date":"2020-03-12T13:41:04","date_gmt":"2020-03-12T12:41:04","guid":{"rendered":"https://www.istec.com/de/?p=17781"},"modified":"2026-07-27T13:55:30","modified_gmt":"2026-07-27T11:55:30","slug":"rod-drop-measurements-for-reciprocating-compressors","status":"publish","type":"post","link":"https://www.istec.com/de/rod-drop-measurements-for-reciprocating-compressors/","title":{"rendered":"Rod drop measurements for reciprocating compressors"},"content":{"rendered":"<div class=\"gray-content-container\">\n<p>This article is part of the whitepaper: &#8220;monitoring mechanical behaviour of reciprocating machinery&#8221;. <a href=\"https://www.istec.com/de/whitepaper-monitoring-mechanical-behaviour-of-reciprocating-machinery/\" target=\"_blank\" rel=\"noopener\">Request the whitepaper here » </a></p>\n</div>\n<p>Rod drop is an important mechanical indicator for gaining insight into rider band wear. This article discusses what is needed to ensure reliable and accurate monitoring of this critical parameter for reciprocating compressors.</p>\n<p>Rider bands are critical components that support the piston while its moving through the cylinder. They are used to correctly position the piston in the cylinder, to prevent metal-to-metal contact between the cylinder wall and the piston. These rider bands wear out over time, which results in a vertical displacement of the piston and the piston rod. To prevent damage to the piston and the cylinder wall, the condition of the rider bands should be monitored.</p>\n<p><strong>Proximity sensors</strong> are used to monitor rider band wear. However, it is difficult to directly monitor the vertical displacement of the piston due to high pressure inside the cylinder. Instead, the vertical displacement of the piston rod is monitored, which is proportional to the drop of the piston. Monitoring vertical rod displacement is therefore a reliable method to monitor rider band wear (figure 1).</p>\n<figure id=\"attachment_17782\" aria-describedby=\"caption-attachment-17782\" style=\"width: 730px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-large wp-image-17782\" src=\"https://www.istec.com/wp-content/uploads/2019/12/RecipSys-werking-2-e1577105708923-730x530.png\" alt=\"\" width=\"730\" height=\"530\" srcset=\"https://img.istec.com/2019/12/RecipSys-werking-2-e1577105708923-730x530.png 730w, https://img.istec.com/2019/12/RecipSys-werking-2-e1577105708923-300x218.png 300w, https://img.istec.com/2019/12/RecipSys-werking-2-e1577105708923-768x558.png 768w, https://img.istec.com/2019/12/RecipSys-werking-2-e1577105708923-1536x1115.png 1536w, https://img.istec.com/2019/12/RecipSys-werking-2-e1577105708923-2048x1487.png 2048w\" sizes=\"auto, (max-width: 730px) 100vw, 730px\" /><figcaption id=\"caption-attachment-17782\" class=\"wp-caption-text\"><strong>Figure 1.</strong> Schematic representation of a piston rod measurement, which is used to monitor rider band wear.</figcaption></figure>\n<p>The proximity sensor must be mounted vertically (90 degree angle) under or above the piston rod, as close to the cylinder as possible (figure 2). Optionally, a second proximity sensor can be mounted in the same way, but positioned horizontally to the piston rod (X-Y monitoring). By installing a second sensor (horizontally) it is possible to measure horizontal displacement of the piston rod, which is necessary to be able to do rod flex measurements.</p>\n<p><strong>Phase reference sensors </strong>are used to filter the displacement signal to the right phase angle. The sensor enables measurements of the piston rod displacement at a specific point during the cycle. The sensor is crucial for reliable monitoring of rider band wear because the vertical displacement of the piston rod must be measured at a specific point during the rotation of the shaft (figure 2).</p>\n<figure id=\"attachment_17783\" aria-describedby=\"caption-attachment-17783\" style=\"width: 730px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-large wp-image-17783\" src=\"https://www.istec.com/wp-content/uploads/2019/12/ebook-reciprocating-machines-rod-drop-1-e1577108225652-730x416.png\" alt=\"\" width=\"730\" height=\"416\" srcset=\"https://img.istec.com/2019/12/ebook-reciprocating-machines-rod-drop-1-e1577108225652-730x416.png 730w, https://img.istec.com/2019/12/ebook-reciprocating-machines-rod-drop-1-e1577108225652-300x171.png 300w, https://img.istec.com/2019/12/ebook-reciprocating-machines-rod-drop-1-e1577108225652-768x438.png 768w, https://img.istec.com/2019/12/ebook-reciprocating-machines-rod-drop-1-e1577108225652-1536x876.png 1536w, https://img.istec.com/2019/12/ebook-reciprocating-machines-rod-drop-1-e1577108225652-2048x1168.png 2048w\" sizes=\"auto, (max-width: 730px) 100vw, 730px\" /><figcaption id=\"caption-attachment-17783\" class=\"wp-caption-text\"><strong>Figure 2</strong>. Schematic overview of the sensor positions for rod drop measurements.</figcaption></figure>\n<h2></h2>\n<h2 style=\"font-family: Ubuntu, sans-serif;\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-31717 alignright\" src=\"https://img.istec.com/2025/01/959ae47f-istec-recipsys-200-300x300.jpg\" alt=\"\" width=\"300\" height=\"300\" srcset=\"https://img.istec.com/2025/01/959ae47f-istec-recipsys-200-300x300.jpg 300w, https://img.istec.com/2025/01/959ae47f-istec-recipsys-200-150x150.jpg 150w, https://img.istec.com/2025/01/959ae47f-istec-recipsys-200.jpg 730w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" /></h2>\n<h2>Istec RecipSys 200</h2>\n<p>The RecipSys 200 is a compact monitoring system for reciprocating compressors. It delivers accurate real-time data of rider band wear, eliminating the need for periodic production shutdowns for manual inspections. The transmitter-based system is affordable and extends the range of compressors which can be monitored.</p>\n<p><a href=\"https://www.istec.com/de/product/recipsys-200/\">Visit this page for more information »</a></p>\n","protected":false},"excerpt":{"rendered":"<p>This article is part of the whitepaper: &#8220;monitoring mechanical behaviour of reciprocating machinery&#8221;. Request the whitepaper here »  Rod drop is an important mechanical indicator for gaining insight into rider band wear. This article discusses what is needed to ensure reliable and accurate monitoring of this critical parameter for reciprocating compressors. Rider bands are critical &hellip; </p>\n","protected":false},"author":3,"featured_media":19007,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[98],"topics":[265,266],"class_list":["post-17781","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized","topics-knowledge","topics-recipsys"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.7 - https://yoast.com/product/yoast-seo-wordpress/ -->\n<title>Rod drop measurements for reciprocating compressors &#8212; Istec</title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" />\n<link rel=\"canonical\" href=\"https://www.istec.com/de/rod-drop-measurements-for-reciprocating-compressors/\" />\n<meta property=\"og:locale\" content=\"de_DE\" />\n<meta property=\"og:type\" content=\"article\" />\n<meta property=\"og:title\" content=\"Rod drop measurements for reciprocating compressors &#8212; Istec\" />\n<meta property=\"og:description\" content=\"This article is part of the whitepaper: &#8220;monitoring mechanical behaviour of reciprocating machinery&#8221;. Request the whitepaper here »  Rod drop is an important mechanical indicator for gaining insight into rider band wear. This article discusses what is needed to ensure reliable and accurate monitoring of this critical parameter for reciprocating compressors. Rider bands are critical &hellip;\" />\n<meta property=\"og:url\" content=\"https://www.istec.com/de/rod-drop-measurements-for-reciprocating-compressors/\" />\n<meta property=\"og:site_name\" content=\"Istec\" />\n<meta property=\"article:published_time\" content=\"2020-03-12T12:41:04+00:00\" />\n<meta property=\"article:modified_time\" content=\"2026-07-27T11:55:30+00:00\" />\n<meta property=\"og:image\" content=\"https://img.istec.com/2020/03/rider-band-monitoring.jpg?q=65\" />\n\t<meta property=\"og:image:width\" content=\"730\" />\n\t<meta property=\"og:image:height\" content=\"270\" />\n\t<meta property=\"og:image:type\" content=\"image/jpeg\" />\n<meta name=\"author\" content=\"istecadmin\" />\n<meta name=\"twitter:card\" content=\"summary_large_image\" />\n<meta name=\"twitter:label1\" content=\"Verfasst von\" />\n\t<meta name=\"twitter:data1\" content=\"istecadmin\" />\n\t<meta name=\"twitter:label2\" content=\"Geschätzte Lesezeit\" />\n\t<meta name=\"twitter:data2\" content=\"3 Minuten\" />\n<script type=\"application/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\/\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\/\\/www.istec.com\\/rod-drop-measurements-for-reciprocating-compressors\\/#article\",\"isPartOf\":{\"@id\":\"https:\\/\\/www.istec.com\\/rod-drop-measurements-for-reciprocating-compressors\\/\"},\"author\":{\"name\":\"istecadmin\",\"@id\":\"https:\\/\\/www.istec.com\\/#\\/schema\\/person\\/04b7a48a774cc6803bde480e419841db\"},\"headline\":\"Rod drop measurements for reciprocating compressors\",\"datePublished\":\"2020-03-12T12:41:04+00:00\",\"dateModified\":\"2026-07-27T11:55:30+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\/\\/www.istec.com\\/rod-drop-measurements-for-reciprocating-compressors\\/\"},\"wordCount\":410,\"publisher\":{\"@id\":\"https:\\/\\/www.istec.com\\/#organization\"},\"image\":{\"@id\":\"https:\\/\\/www.istec.com\\/rod-drop-measurements-for-reciprocating-compressors\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\/\\/img.istec.com\\/2020\\/03\\/rider-band-monitoring.jpg?q=65\",\"articleSection\":[\"Uncategorized\"],\"inLanguage\":\"de\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\/\\/www.istec.com\\/rod-drop-measurements-for-reciprocating-compressors\\/\",\"url\":\"https:\\/\\/www.istec.com\\/rod-drop-measurements-for-reciprocating-compressors\\/\",\"name\":\"Rod drop measurements for reciprocating compressors &#8212; Istec\",\"isPartOf\":{\"@id\":\"https:\\/\\/www.istec.com\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\/\\/www.istec.com\\/rod-drop-measurements-for-reciprocating-compressors\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\/\\/www.istec.com\\/rod-drop-measurements-for-reciprocating-compressors\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\/\\/img.istec.com\\/2020\\/03\\/rider-band-monitoring.jpg?q=65\",\"datePublished\":\"2020-03-12T12:41:04+00:00\",\"dateModified\":\"2026-07-27T11:55:30+00:00\",\"breadcrumb\":{\"@id\":\"https:\\/\\/www.istec.com\\/rod-drop-measurements-for-reciprocating-compressors\\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\/\\/www.istec.com\\/rod-drop-measurements-for-reciprocating-compressors\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\/\\/www.istec.com\\/rod-drop-measurements-for-reciprocating-compressors\\/#primaryimage\",\"url\":\"https:\\/\\/img.istec.com\\/2020\\/03\\/rider-band-monitoring.jpg?q=65\",\"contentUrl\":\"https:\\/\\/img.istec.com\\/2020\\/03\\/rider-band-monitoring.jpg?q=65\",\"width\":730,\"height\":270},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\/\\/www.istec.com\\/rod-drop-measurements-for-reciprocating-compressors\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\/\\/www.istec.com\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Rod drop measurements for reciprocating compressors\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\/\\/www.istec.com\\/#website\",\"url\":\"https:\\/\\/www.istec.com\\/\",\"name\":\"Istec\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\/\\/www.istec.com\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\/\\/www.istec.com\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\\/\\/www.istec.com\\/#organization\",\"name\":\"Istec\",\"url\":\"https:\\/\\/www.istec.com\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\/\\/www.istec.com\\/#\\/schema\\/logo\\/image\\/\",\"url\":\"https:\\/\\/img.istec.com\\/2018\\/01\\/istec-international-logo.jpg?q=65\",\"contentUrl\":\"https:\\/\\/img.istec.com\\/2018\\/01\\/istec-international-logo.jpg?q=65\",\"width\":83,\"height\":88,\"caption\":\"Istec\"},\"image\":{\"@id\":\"https:\\/\\/www.istec.com\\/#\\/schema\\/logo\\/image\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\/\\/www.istec.com\\/#\\/schema\\/person\\/04b7a48a774cc6803bde480e419841db\",\"name\":\"istecadmin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\/\\/secure.gravatar.com\\/avatar\\/ef2104d69abb108ecc953f2504e75cff42eef5e48ce6e93be2b0814a1056f0aa?s=96&d=mm&r=g\",\"url\":\"https:\\/\\/secure.gravatar.com\\/avatar\\/ef2104d69abb108ecc953f2504e75cff42eef5e48ce6e93be2b0814a1056f0aa?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\/\\/secure.gravatar.com\\/avatar\\/ef2104d69abb108ecc953f2504e75cff42eef5e48ce6e93be2b0814a1056f0aa?s=96&d=mm&r=g\",\"caption\":\"istecadmin\"},\"url\":\"https:\\/\\/www.istec.com\\/specialist\\/istecadmin\\/\"}]}</script>\n<!-- / Yoast SEO plugin. -->","yoast_head_json":{"title":"Stangenabsenkungsmessungen für Kolbenkompressoren — Istec","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https://www.istec.com/de/rod-drop-measurements-for-reciprocating-compressors/","og_locale":"de_DE","og_type":"article","og_title":"Rod drop measurements for reciprocating compressors &#8212; Istec","og_description":"This article is part of the whitepaper: &#8220;monitoring mechanical behaviour of reciprocating machinery&#8221;. Request the whitepaper here »  Rod drop is an important mechanical indicator for gaining insight into rider band wear. This article discusses what is needed to ensure reliable and accurate monitoring of this critical parameter for reciprocating compressors. Rider bands are critical &hellip;","og_url":"https://www.istec.com/de/rod-drop-measurements-for-reciprocating-compressors/","og_site_name":"Istec","article_published_time":"2020-03-12T12:41:04+00:00","article_modified_time":"2026-07-27T11:55:30+00:00","og_image":[{"width":730,"height":270,"url":"https://img.istec.com/2020/03/rider-band-monitoring.jpg?q=65","type":"image/jpeg"}],"author":"istecadmin","twitter_card":"summary_large_image","twitter_misc":{"Verfasst von":"istecadmin","Geschätzte Lesezeit":"3 Minuten"},"schema":{"@context":"https://schema.org","@graph":[{"@type":"Article","@id":"https://www.istec.com/de/rod-drop-measurements-for-reciprocating-compressors/#article","isPartOf":{"@id":"https://www.istec.com/de/rod-drop-measurements-for-reciprocating-compressors/"},"author":{"name":"istecadmin","@id":"https://www.istec.com/de/#/schema/person/04b7a48a774cc6803bde480e419841db"},"headline":"Rod drop measurements for reciprocating compressors","datePublished":"2020-03-12T12:41:04+00:00","dateModified":"2026-07-27T11:55:30+00:00","mainEntityOfPage":{"@id":"https://www.istec.com/de/rod-drop-measurements-for-reciprocating-compressors/"},"wordCount":410,"publisher":{"@id":"https://www.istec.com/de/#organization"},"image":{"@id":"https://www.istec.com/de/rod-drop-measurements-for-reciprocating-compressors/#primaryimage"},"thumbnailUrl":"https://img.istec.com/2020/03/rider-band-monitoring.jpg?q=65","articleSection":["Uncategorized"],"inLanguage":"de"},{"@type":"WebPage","@id":"https://www.istec.com/de/rod-drop-measurements-for-reciprocating-compressors/","url":"https://www.istec.com/de/rod-drop-measurements-for-reciprocating-compressors/","name":"Rod drop measurements for reciprocating compressors &#8212; Istec","isPartOf":{"@id":"https://www.istec.com/de/#website"},"primaryImageOfPage":{"@id":"https://www.istec.com/de/rod-drop-measurements-for-reciprocating-compressors/#primaryimage"},"image":{"@id":"https://www.istec.com/de/rod-drop-measurements-for-reciprocating-compressors/#primaryimage"},"thumbnailUrl":"https://img.istec.com/2020/03/rider-band-monitoring.jpg?q=65","datePublished":"2020-03-12T12:41:04+00:00","dateModified":"2026-07-27T11:55:30+00:00","breadcrumb":{"@id":"https://www.istec.com/de/rod-drop-measurements-for-reciprocating-compressors/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https://www.istec.com/de/rod-drop-measurements-for-reciprocating-compressors/"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https://www.istec.com/de/rod-drop-measurements-for-reciprocating-compressors/#primaryimage","url":"https://img.istec.com/2020/03/rider-band-monitoring.jpg?q=65","contentUrl":"https://img.istec.com/2020/03/rider-band-monitoring.jpg?q=65","width":730,"height":270},{"@type":"BreadcrumbList","@id":"https://www.istec.com/de/rod-drop-measurements-for-reciprocating-compressors/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://www.istec.com/de/"},{"@type":"ListItem","position":2,"name":"Rod drop measurements for reciprocating compressors"}]},{"@type":"WebSite","@id":"https://www.istec.com/de/#website","url":"https://www.istec.com/de/","name":"Istec","description":"","publisher":{"@id":"https://www.istec.com/de/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://www.istec.com/de/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https://www.istec.com/de/#organization","name":"Istec","url":"https://www.istec.com/de/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https://www.istec.com/de/#/schema/logo/image/","url":"https://img.istec.com/2018/01/istec-international-logo.jpg?q=65","contentUrl":"https://img.istec.com/2018/01/istec-international-logo.jpg?q=65","width":83,"height":88,"caption":"Istec"},"image":{"@id":"https://www.istec.com/de/#/schema/logo/image/"}},{"@type":"Person","@id":"https://www.istec.com/de/#/schema/person/04b7a48a774cc6803bde480e419841db","name":"istecadmin","image":{"@type":"ImageObject","inLanguage":"de","@id":"https://secure.gravatar.com/avatar/ef2104d69abb108ecc953f2504e75cff42eef5e48ce6e93be2b0814a1056f0aa?s=96&d=mm&r=g","url":"https://secure.gravatar.com/avatar/ef2104d69abb108ecc953f2504e75cff42eef5e48ce6e93be2b0814a1056f0aa?s=96&d=mm&r=g","contentUrl":"https://secure.gravatar.com/avatar/ef2104d69abb108ecc953f2504e75cff42eef5e48ce6e93be2b0814a1056f0aa?s=96&d=mm&r=g","caption":"istecadmin"},"url":"https://www.istec.com/de/specialist/istecadmin/"}]}},"_links":{"self":[{"href":"https://www.istec.com/de/wp-json/wp/v2/posts/17781","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https://www.istec.com/de/wp-json/wp/v2/posts"}],"about":[{"href":"https://www.istec.com/de/wp-json/wp/v2/types/post"}],"author":[{"embeddable":true,"href":"https://www.istec.com/de/wp-json/wp/v2/users/3"}],"replies":[{"embeddable":true,"href":"https://www.istec.com/de/wp-json/wp/v2/comments?post=17781"}],"version-history":[{"count":43,"href":"https://www.istec.com/de/wp-json/wp/v2/posts/17781/revisions"}],"predecessor-version":[{"id":37533,"href":"https://www.istec.com/de/wp-json/wp/v2/posts/17781/revisions/37533"}],"wp:featuredmedia":[{"embeddable":true,"href":"https://www.istec.com/de/wp-json/wp/v2/media/19007"}],"wp:attachment":[{"href":"https://www.istec.com/de/wp-json/wp/v2/media?parent=17781"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https://www.istec.com/de/wp-json/wp/v2/categories?post=17781"},{"taxonomy":"topics","embeddable":true,"href":"https://www.istec.com/de/wp-json/wp/v2/topics?post=17781"}],"curies":[{"name":"wp","href":"https://api.w.org/{rel}","templated":true}]}}