{"id":20631,"date":"2020-08-28T13:10:58","date_gmt":"2020-08-28T11:10:58","guid":{"rendered":"https://www.istec.com/fr/?page_id=20631"},"modified":"2024-04-24T10:45:31","modified_gmt":"2024-04-24T08:45:31","slug":"speedsys-ods-faq","status":"publish","type":"page","link":"https://www.istec.com/fr/speedsys-ods-faq/","title":{"rendered":"SpeedSys ODS &#8211; FAQ"},"content":{"rendered":"<div class='content-column two_third'><div style=\"padding-top:10px;padding-right:30px;\"><p><span class=\"alt-link\"><a href=\"https://www.istec.com/fr/product/speedsys-200/\">« Back to product page of SpeedSys 200</a></span></p>\n<p><span class=\"alt-link\"><a href=\"https://www.istec.com/fr/product/speedsys-300/\">« Back to product page of SpeedSys 300</a></span></p>\n<h2>General FAQs</h2>\n<div class=\"accordion\" id=\"accordion79091\"><div class=\"panel panel-default\"><div class=\"panel-heading\" id=\"heading79091-1\"><span class=\"panel-title\"><a class=\"panel-title-link collapsed\" data-toggle=\"collapse\" data-target=\"#collapse79091-1\" aria-expanded=\"true\" aria-controls=\"collapse79091-1\"><strong>What does SpeedSys ODS refer to?</strong></a></span></div><div id=\"collapse79091-1\" class=\"panel-collapse collapse\" aria-labelledby=\"heading79091-1\" data-parent=\"#accordion\"><div class=\"panel-body\"><p>SpeedSys ODS is the collective name for the SpeedSys 200 and SpeedSys 300, which are part of the SpeedSys product line which also consists of the SpeedSys tachometers T10, T20 &amp; T30. SpeedSys ODS are a SIL-rated overspeed detection system (ODS) with ATEX-certified input circuitry and can be integrated in SIL-rated decision chains, like emergency shutdown systems.<br /><ul><li>SIL3 in a setup with HFT ≥ 1 (1oo2, 1oo3 or 2oo3)</li><li>Binary input (for remotely triggering a test and/or reset)</li><li>Binary output</li><li>Modbus RTU RS-485 (read-only)</li></ul></div></div></div><div class=\"panel panel-default\"><div class=\"panel-heading\" id=\"heading79091-2\"><span class=\"panel-title\"><a class=\"panel-title-link collapsed\" data-toggle=\"collapse\" data-target=\"#collapse79091-2\" aria-expanded=\"true\" aria-controls=\"collapse79091-2\"><strong>Which sensors are compatible with SpeedSys ODS?</strong></a></span></div><div id=\"collapse79091-2\" class=\"panel-collapse collapse\" aria-labelledby=\"heading79091-2\" data-parent=\"#accordion\"><div class=\"panel-body\"><p>To feature flexibility and easy retrofitting SpeedSys ODS works with the three most commonly found sensors in the field: MPU/VR, Hall effect and eddy current/proximity.<br /></div></div></div><div class=\"panel panel-default\"><div class=\"panel-heading\" id=\"heading79091-3\"><span class=\"panel-title\"><a class=\"panel-title-link collapsed\" data-toggle=\"collapse\" data-target=\"#collapse79091-3\" aria-expanded=\"true\" aria-controls=\"collapse79091-3\"><strong>Which detection functionalities does SpeedSys ODS have?</strong></a></span></div><div id=\"collapse79091-3\" class=\"panel-collapse collapse\" aria-labelledby=\"heading79091-3\" data-parent=\"#accordion\"><div class=\"panel-body\"><p><em>SpeedSys 200</em></p><p>Overspeed, acceleration and underspeed. All of these can be simultaneously configured to all four relays. This allows for maximum configuration flexibility</p><p><em>SpeedSys 300</em></p><p>Overspeed, acceleration and underspeed. All of these can be simultaneously configured to all four relays and the binary output (SpeedSys 300 only). This allows for maximum configuration flexibility</p></div></div></div><div class=\"panel panel-default\"><div class=\"panel-heading\" id=\"heading79091-4\"><span class=\"panel-title\"><a class=\"panel-title-link collapsed\" data-toggle=\"collapse\" data-target=\"#collapse79091-4\" aria-expanded=\"true\" aria-controls=\"collapse79091-4\"><strong>What is the concept behind the proof test and how is it integrated into SpeedSys ODS?</strong></a></span></div><div id=\"collapse79091-4\" class=\"panel-collapse collapse\" aria-labelledby=\"heading79091-4\" data-parent=\"#accordion\"><div class=\"panel-body\"><p><em>SpeedSys 200</em></p><p>By periodically testing (parts of) a system the PFD (probability of failure of demand) is reduced, leading to higher reliability. SpeedSys 200 allows for proof testing of tailing equipment by switching its relays through the software. The transmitter itself has a typical proof test interval of ≥ 10 years.</p><p><em>SpeedSys 300</em></p><p>By periodically testing (parts of) a system the PFD (probability of failure of demand) is reduced, leading to higher reliability. SpeedSys 300 allows for proof testing of tailing equipment by switching its relays through the software or activating the binary input. The transmitter itself has a typical proof test interval of ≥ 10 years.</p></div></div></div><div class=\"panel panel-default\"><div class=\"panel-heading\" id=\"heading79091-5\"><span class=\"panel-title\"><a class=\"panel-title-link collapsed\" data-toggle=\"collapse\" data-target=\"#collapse79091-5\" aria-expanded=\"true\" aria-controls=\"collapse79091-5\"><strong>What cable lengths can I use between my sensor and my SpeedSys module?</strong></a></span></div><div id=\"collapse79091-5\" class=\"panel-collapse collapse\" aria-labelledby=\"heading79091-5\" data-parent=\"#accordion\"><div class=\"panel-body\"><p>The sensor cable lengths are not defined by the SpeedSys transmitter, but by the sensor, application specifics and the electromagnetic environment.</p></div></div></div><div class=\"panel panel-default\"><div class=\"panel-heading\" id=\"heading79091-6\"><span class=\"panel-title\"><a class=\"panel-title-link collapsed\" data-toggle=\"collapse\" data-target=\"#collapse79091-6\" aria-expanded=\"true\" aria-controls=\"collapse79091-6\"><strong>What is the maximum length of the USB cable that can be connected between a computer and the transmitter.</strong></a></span></div><div id=\"collapse79091-6\" class=\"panel-collapse collapse\" aria-labelledby=\"heading79091-6\" data-parent=\"#accordion\"><div class=\"panel-body\"><p>The standard maximum length for USB 2.0 is 5 m (16 ft).</p></div></div></div><div class=\"panel panel-default\"><div class=\"panel-heading\" id=\"heading79091-7\"><span class=\"panel-title\"><a class=\"panel-title-link collapsed\" data-toggle=\"collapse\" data-target=\"#collapse79091-7\" aria-expanded=\"true\" aria-controls=\"collapse79091-7\"><strong>In my ATEX areas, do I need to install barriers on the cables coming from the sensors?</strong></a></span></div><div id=\"collapse79091-7\" class=\"panel-collapse collapse\" aria-labelledby=\"heading79091-7\" data-parent=\"#accordion\"><div class=\"panel-body\"><p>No, the sensor input circuitry of the SpeedSys 200 is ATEX certified (zone 0 &amp; 20). This gives the hardware the advanced ability to monitor the sensors and detect sensor failure. With external barriers this is not always possible.</p></div></div></div><div class=\"panel panel-default\"><div class=\"panel-heading\" id=\"heading79091-8\"><span class=\"panel-title\"><a class=\"panel-title-link collapsed\" data-toggle=\"collapse\" data-target=\"#collapse79091-8\" aria-expanded=\"true\" aria-controls=\"collapse79091-8\"><strong>Can the SpeedSys modules be programmed before installation?</strong></a></span></div><div id=\"collapse79091-8\" class=\"panel-collapse collapse\" aria-labelledby=\"heading79091-8\" data-parent=\"#accordion\"><div class=\"panel-body\"><p>A configuration file can be prepared ‘off-line’ after which this can be uploaded onto a powered SpeedSys unit.</p></div></div></div><div class=\"panel panel-default\"><div class=\"panel-heading\" id=\"heading79091-9\"><span class=\"panel-title\"><a class=\"panel-title-link collapsed\" data-toggle=\"collapse\" data-target=\"#collapse79091-9\" aria-expanded=\"true\" aria-controls=\"collapse79091-9\"><strong>Is a SpeedSys module HOT swappable (so without interrupting the electricity supply)?</strong></a></span></div><div id=\"collapse79091-9\" class=\"panel-collapse collapse\" aria-labelledby=\"heading79091-9\" data-parent=\"#accordion\"><div class=\"panel-body\"><p>The configuration of the commissioned unit needs to be uploaded to the replacing unit after that the units can be swapped without interrupting the power.</p></div></div></div><div class=\"panel panel-default\"><div class=\"panel-heading\" id=\"heading79091-10\"><span class=\"panel-title\"><a class=\"panel-title-link collapsed\" data-toggle=\"collapse\" data-target=\"#collapse79091-10\" aria-expanded=\"true\" aria-controls=\"collapse79091-10\"><strong>Does SpeedSys ODS has a redundant power supply?</strong></a></span></div><div id=\"collapse79091-10\" class=\"panel-collapse collapse\" aria-labelledby=\"heading79091-10\" data-parent=\"#accordion\"><div class=\"panel-body\"><p>Yes, SpeedSys ODS has a redundant power input. These inputs are internally connected by ORing diodes after which the main power supply is checked to be from 18 to 36 VDC. Therefore SpeedSys ODS will work fine on a single power input, but also no alarm is raised if just one power input fails.</p></div></div></div><div class=\"panel panel-default\"><div class=\"panel-heading\" id=\"heading79091-11\"><span class=\"panel-title\"><a class=\"panel-title-link collapsed\" data-toggle=\"collapse\" data-target=\"#collapse79091-11\" aria-expanded=\"true\" aria-controls=\"collapse79091-11\"><strong>Does SpeedSys ODS come in a rack mounted version?</strong></a></span></div><div id=\"collapse79091-11\" class=\"panel-collapse collapse\" aria-labelledby=\"heading79091-11\" data-parent=\"#accordion\"><div class=\"panel-body\"><p>The SpeedSys modules are mounted on a DIN rail, but a 19” rack adapter is available.</p></div></div></div><div class=\"panel panel-default\"><div class=\"panel-heading\" id=\"heading79091-12\"><span class=\"panel-title\"><a class=\"panel-title-link collapsed\" data-toggle=\"collapse\" data-target=\"#collapse79091-12\" aria-expanded=\"true\" aria-controls=\"collapse79091-12\"><strong>Can I reset my password if it is lost?</strong></a></span></div><div id=\"collapse79091-12\" class=\"panel-collapse collapse\" aria-labelledby=\"heading79091-12\" data-parent=\"#accordion\"><div class=\"panel-body\"><p>No, the password in SpeedSys ODS can only be set by the manufacturer. Be careful!</p></div></div></div><div class=\"panel panel-default\"><div class=\"panel-heading\" id=\"heading79091-13\"><span class=\"panel-title\"><a class=\"panel-title-link collapsed\" data-toggle=\"collapse\" data-target=\"#collapse79091-13\" aria-expanded=\"true\" aria-controls=\"collapse79091-13\"><strong>Can I turn the password off for SpeedSys ODS?</strong></a></span></div><div id=\"collapse79091-13\" class=\"panel-collapse collapse\" aria-labelledby=\"heading79091-13\" data-parent=\"#accordion\"><div class=\"panel-body\"><p>No, SpeedSys ODS is part of the critical protection of the machine and can therefore only be programmed by authorized personnel.</p></div></div></div><div class=\"panel panel-default\"><div class=\"panel-heading\" id=\"heading79091-14\"><span class=\"panel-title\"><a class=\"panel-title-link collapsed\" data-toggle=\"collapse\" data-target=\"#collapse79091-14\" aria-expanded=\"true\" aria-controls=\"collapse79091-14\"><strong>What is the delivery time of SpeedSys ODS?</strong></a></span></div><div id=\"collapse79091-14\" class=\"panel-collapse collapse\" aria-labelledby=\"heading79091-14\" data-parent=\"#accordion\"><div class=\"panel-body\"><p>It is our intention always to have a sufficient stock supply resulting in a delivery time of 1-2 weeks. For larger quantities please inquire with sales@istec.com.</p></div></div></div></div>\n<h2>SpeedSys 300 specific FAQs</h2>\n<div class=\"accordion\" id=\"accordion16002\"><div class=\"panel panel-default\"><div class=\"panel-heading\" id=\"heading16002-1\"><span class=\"panel-title\"><a class=\"panel-title-link collapsed\" data-toggle=\"collapse\" data-target=\"#collapse16002-1\" aria-expanded=\"true\" aria-controls=\"collapse16002-1\"><strong>Can the proof test be activated through the MODBUS?</strong></a></span></div><div id=\"collapse16002-1\" class=\"panel-collapse collapse\" aria-labelledby=\"heading16002-1\" data-parent=\"#accordion\"><div class=\"panel-body\"><p>The proof test can be activated remotely on the SpeedSys 300, but not through the MODBUS. SpeedSys 300 has a special binary input.</p></div></div></div><div class=\"panel panel-default\"><div class=\"panel-heading\" id=\"heading16002-2\"><span class=\"panel-title\"><a class=\"panel-title-link collapsed\" data-toggle=\"collapse\" data-target=\"#collapse16002-2\" aria-expanded=\"true\" aria-controls=\"collapse16002-2\"><strong>Are separate SpeedSys transmitters identifiable on a single MODBUS line?</strong></a></span></div><div id=\"collapse16002-2\" class=\"panel-collapse collapse\" aria-labelledby=\"heading16002-2\" data-parent=\"#accordion\"><div class=\"panel-body\"><p>Yes, every transmitter gets a unique address (max. 247 per MODBUS line) within the MODBUS protocol from which information can be requested.</p></div></div></div><div class=\"panel panel-default\"><div class=\"panel-heading\" id=\"heading16002-3\"><span class=\"panel-title\"><a class=\"panel-title-link collapsed\" data-toggle=\"collapse\" data-target=\"#collapse16002-3\" aria-expanded=\"true\" aria-controls=\"collapse16002-3\"><strong>Can I obtain SIL3 protection for my machine with a one SpeedSys300 modules</strong></a></span></div><div id=\"collapse16002-3\" class=\"panel-collapse collapse\" aria-labelledby=\"heading16002-3\" data-parent=\"#accordion\"><div class=\"panel-body\"><p>No, SIL3 protection can only be obtained with a system with a hardware fault tolerance of 1 or higher (HFT ≥ 1)</p></div></div></div></div></div></div>\n<p>&nbsp;</p>\n<div class='content-column one_third last_column'><div style=\"padding-left:50px;\"><p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-medium wp-image-26716\" src=\"https://img.istec.com/2020/12/speedsys-200300-e1680681047310-300x250.png\" alt=\"\" width=\"300\" height=\"250\" /></p></div></div><div class='clear_column'></div>\n","protected":false},"excerpt":{"rendered":"<p>&nbsp;</p>\n","protected":false},"author":3,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-20631","page","type-page","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.7 - https://yoast.com/product/yoast-seo-wordpress/ -->\n<title>SpeedSys ODS - FAQ &#8212; Istec</title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" />\n<link rel=\"canonical\" href=\"https://www.istec.com/fr/speedsys-ods-faq/\" />\n<meta property=\"og:locale\" content=\"fr_FR\" />\n<meta property=\"og:type\" content=\"article\" />\n<meta property=\"og:title\" content=\"SpeedSys ODS - FAQ &#8212; Istec\" />\n<meta property=\"og:description\" content=\"&nbsp;\" />\n<meta property=\"og:url\" content=\"https://www.istec.com/fr/speedsys-ods-faq/\" />\n<meta property=\"og:site_name\" content=\"Istec\" />\n<meta property=\"article:modified_time\" content=\"2024-04-24T08:45:31+00:00\" />\n<meta property=\"og:image\" content=\"https://img.istec.com/2020/12/speedsys-200300-e1680681047310-300x250.png\" />\n<meta name=\"twitter:card\" content=\"summary_large_image\" />\n<meta name=\"twitter:label1\" content=\"Est. reading time\" />\n\t<meta name=\"twitter:data1\" content=\"5 minutes\" />\n<script type=\"application/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\/\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\/\\/www.istec.com\\/speedsys-ods-faq\\/\",\"url\":\"https:\\/\\/www.istec.com\\/speedsys-ods-faq\\/\",\"name\":\"SpeedSys ODS - FAQ &#8212; Istec\",\"isPartOf\":{\"@id\":\"https:\\/\\/www.istec.com\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\/\\/www.istec.com\\/speedsys-ods-faq\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\/\\/www.istec.com\\/speedsys-ods-faq\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\/\\/img.istec.com\\/2020\\/12\\/speedsys-200300-e1680681047310-300x250.png\",\"datePublished\":\"2020-08-28T11:10:58+00:00\",\"dateModified\":\"2024-04-24T08:45:31+00:00\",\"breadcrumb\":{\"@id\":\"https:\\/\\/www.istec.com\\/speedsys-ods-faq\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\/\\/www.istec.com\\/speedsys-ods-faq\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\/\\/www.istec.com\\/speedsys-ods-faq\\/#primaryimage\",\"url\":\"https:\\/\\/img.istec.com\\/2020\\/12\\/speedsys-200300-e1680681047310-300x250.png\",\"contentUrl\":\"https:\\/\\/img.istec.com\\/2020\\/12\\/speedsys-200300-e1680681047310-300x250.png\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\/\\/www.istec.com\\/speedsys-ods-faq\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\/\\/www.istec.com\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"SpeedSys ODS &#8211; FAQ\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\/\\/www.istec.com\\/#website\",\"url\":\"https:\\/\\/www.istec.com\\/\",\"name\":\"Istec\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\/\\/www.istec.com\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\/\\/www.istec.com\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\/\\/www.istec.com\\/#organization\",\"name\":\"Istec\",\"url\":\"https:\\/\\/www.istec.com\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\/\\/www.istec.com\\/#\\/schema\\/logo\\/image\\/\",\"url\":\"https:\\/\\/img.istec.com\\/2018\\/01\\/istec-international-logo.jpg?q=65\",\"contentUrl\":\"https:\\/\\/img.istec.com\\/2018\\/01\\/istec-international-logo.jpg?q=65\",\"width\":83,\"height\":88,\"caption\":\"Istec\"},\"image\":{\"@id\":\"https:\\/\\/www.istec.com\\/#\\/schema\\/logo\\/image\\/\"}}]}</script>\n<!-- / Yoast SEO plugin. -->","yoast_head_json":{"title":"SpeedSys ODS - FAQ — Istec","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https://www.istec.com/fr/speedsys-ods-faq/","og_locale":"fr_FR","og_type":"article","og_title":"SpeedSys ODS - FAQ &#8212; Istec","og_description":"&nbsp;","og_url":"https://www.istec.com/fr/speedsys-ods-faq/","og_site_name":"Istec","article_modified_time":"2024-04-24T08:45:31+00:00","og_image":[{"url":"https://img.istec.com/2020/12/speedsys-200300-e1680681047310-300x250.png","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"5 minutes"},"schema":{"@context":"https://schema.org","@graph":[{"@type":"WebPage","@id":"https://www.istec.com/fr/speedsys-ods-faq/","url":"https://www.istec.com/fr/speedsys-ods-faq/","name":"SpeedSys ODS - FAQ &#8212; Istec","isPartOf":{"@id":"https://www.istec.com/fr/#website"},"primaryImageOfPage":{"@id":"https://www.istec.com/fr/speedsys-ods-faq/#primaryimage"},"image":{"@id":"https://www.istec.com/fr/speedsys-ods-faq/#primaryimage"},"thumbnailUrl":"https://img.istec.com/2020/12/speedsys-200300-e1680681047310-300x250.png","datePublished":"2020-08-28T11:10:58+00:00","dateModified":"2024-04-24T08:45:31+00:00","breadcrumb":{"@id":"https://www.istec.com/fr/speedsys-ods-faq/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https://www.istec.com/fr/speedsys-ods-faq/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https://www.istec.com/fr/speedsys-ods-faq/#primaryimage","url":"https://img.istec.com/2020/12/speedsys-200300-e1680681047310-300x250.png","contentUrl":"https://img.istec.com/2020/12/speedsys-200300-e1680681047310-300x250.png"},{"@type":"BreadcrumbList","@id":"https://www.istec.com/fr/speedsys-ods-faq/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://www.istec.com/fr/"},{"@type":"ListItem","position":2,"name":"SpeedSys ODS &#8211; FAQ"}]},{"@type":"WebSite","@id":"https://www.istec.com/fr/#website","url":"https://www.istec.com/fr/","name":"Istec","description":"","publisher":{"@id":"https://www.istec.com/fr/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://www.istec.com/fr/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https://www.istec.com/fr/#organization","name":"Istec","url":"https://www.istec.com/fr/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https://www.istec.com/fr/#/schema/logo/image/","url":"https://img.istec.com/2018/01/istec-international-logo.jpg?q=65","contentUrl":"https://img.istec.com/2018/01/istec-international-logo.jpg?q=65","width":83,"height":88,"caption":"Istec"},"image":{"@id":"https://www.istec.com/fr/#/schema/logo/image/"}}]}},"_links":{"self":[{"href":"https://www.istec.com/fr/wp-json/wp/v2/pages/20631","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https://www.istec.com/fr/wp-json/wp/v2/pages"}],"about":[{"href":"https://www.istec.com/fr/wp-json/wp/v2/types/page"}],"author":[{"embeddable":true,"href":"https://www.istec.com/fr/wp-json/wp/v2/users/3"}],"replies":[{"embeddable":true,"href":"https://www.istec.com/fr/wp-json/wp/v2/comments?post=20631"}],"version-history":[{"count":18,"href":"https://www.istec.com/fr/wp-json/wp/v2/pages/20631/revisions"}],"predecessor-version":[{"id":29574,"href":"https://www.istec.com/fr/wp-json/wp/v2/pages/20631/revisions/29574"}],"wp:attachment":[{"href":"https://www.istec.com/fr/wp-json/wp/v2/media?parent=20631"}],"curies":[{"name":"wp","href":"https://api.w.org/{rel}","templated":true}]}}